Requirements & Schedule of
Regulations
Requirements
Aluminum Carport Requirements
- APPLICATION - Completed building permit and plan examination
application.
- SCALED SITE PLAN - This is a bird’s eye view of the property with
current structures showing dimensions; property lines; measurement
between structures and property lines; and diagram of the addition and
where it will be placed on the house.
- WIND AND SNOW LOAD CALCULATIONS - from the manufacturer.
- ELEVATION - Diagram(s) looking directly at all sides of structure.
- FOUNDATION DRAWING - must have frost-free, 42” foundation - due
to becoming a sail in high winds.
- MUST MEET SET-BACK AND LOT FILL REQUIREMENTS. (The requirements
can be found, by clicking here,
to be directed to the table below.)
New Home Or Building Addition Application Requirements
The following information is required when applying for a building
permit for an addition to a home, new home or a new commercial building:
- APPLICATION - Completed building permit and plan examination
application.
- SITE PLAN - This is a bird’s eye view of the property with current
structures showing dimensions; property lines; measurement between
structures and property lines; and diagram of the addition and where
it will be placed on the house.
- FOUNDATION PLAN - This is a diagram of the foundation plan showing
the depth of the wall in the ground and the thickness of the walls.
- FIRST FLOOR PLAN - Diagram and label rooms with dimensions,
location of doors and windows and their sizes.
- ELEVATION - Diagram(s) looking directly at all sides of structure.
- WALL SECTION - This form will be available in the Forms &
Affidavits section of our website soon!

Inspection Requirements
The following inspections will be required during the process of your
construction project. Twenty-four (24) hour notice is required for
each inspection. Please call (517) 725-0535 to schedule
inspections, Monday through Friday. Failed and incomplete
installations will require an additional inspection and resulting fee of
$30.
- SITE INSPECTION - To determine compliance with setback and
sideline requirements.
- FOOTING INSPECTION - Forms and/or elevation stakes are set, but
before concrete is poured.
- BACKFILL INSPECTION - Basement walls are up; parging and
bituminous materials are applied, drain tiles and peastone are in
place, or if wood foundation – 6 mil visqueen is in place.
- UNDERGROUND PLUMBING INSPECTION - All drain and water lines that
will be covered with concrete are installed, but before fill or
concrete is installed.
- ROUGH FRAME INSPECTION - All wood framing and masonry are
installed. Also, when all exterior doors, windows and roofing
are installed, but before any insulation or wall coverings are
installed. All rough plumbing, electrical and heating is roughed
in.
- ROUGH ELECTRICAL INSPECTION - Wire is drawn and boxes made up (no
fixtures installed) and service is ready to release to Consumers
Energy. NOTE: An extra fee is charged for service
inspections made at any other time.
- ROUGH PLUMBING INSPECTION - All water and drain lines are in and
properly supported, but before any insulation or wall covering is
installed.
- ROUGH MECHANICAL INSPECTION - When all mechanical appliances and
required ducts and vents are installed, but before any insulation or
wall covering is installed.
Other Inspections
Required (Where Applicable)
- FINAL INSPECTION FOR OCCUPANCY - Building must be entirely
complete and ready to occupy. This includes all porches, decks,
trim, carpet, fixtures, and appliances that will be a permanent part
of the unit.
- SWIMMING POOL INSPECTION - (In-ground or above ground) site
inspection and electrical bonding and branch circuit inspection.
- POLE STRUCTURES - Post holes have been dug and are ready for
concrete and poles, a footing inspection is required. A final
inspection is needed when the structure is complete.
- DECKS - When post holes have been dug and are ready for poles and
concrete, a footing inspection is required. A final inspection
is needed when the deck railings and steps are complete.
- ELECTRICAL SERVICE UPGRADE - When meter socket, mast, main
disconnect, and grounding electrode are installed (Consumer’s Energy
must determine the location and approve all service changes).
Unattached Garage Requirements
The following information is required when applying for a building
permit for an unattached garage:
- APPLICATION - Completed building permit and plan examination
application
- SITE PLAN - This is a bird’s eye view of the property with current
structures showing dimensions; property lines; measurement between
structures and property lines; and diagram of the garage and where it
will be placed on the site.
- Cross Section Detached Garage on Slab information will be
available online soon!

Schedule of Regulations
Article XVI
Section 38.351: Schedule limiting height bulk, density and area by
zoning district.
(Click
here to be directed to Chapter 38 of Owosso City Code)
| ZONING
DISTRICT |
MINIMUM
ZONING LOT SIZE PER DWELLING UNIT |
MAXIMUM HEIGHT OF STRUCTURES
(In Feet) |
MINIMUM YARD SETBACK
(Per Lot - In Feet) |
MINIMUM FLOOR AREA PER UNIT
(Sq. Feet) |
MAXIMUM % OF LOT AREA COVERED
(By All Buildings) |
| Area in Sq. Feet |
Width in Feet |
Front |
Each Side |
Rear |
|
|
|
|
|
|
|
|
|
R-1
One-Family Res. |
7,200 (a) |
60 |
30 |
25 (b,t) |
8 (b,c) |
35 (b) |
864 (u,v) |
25% |
R-2
Two-Family Res. |
4,000 |
33 |
30 |
25 (b,t) |
8 (b,c) |
35 (b) |
750 |
25% |
RT-1
Attached One-Family |
4,000 |
|
30 |
30 (d) |
20 (d) |
35 (d) |
(i) |
25% |
RM-1
Multiple Family |
(e,f) |
(e,f) |
35 |
30 (d,h) |
20 (d,h) |
30 (d,h) |
(i) |
25% |
RM-2
Multiple Family |
(f,g) |
(f,g) |
70 |
30 (d,h) |
20 (d,h) |
30 (d,h) |
(i) |
25% |
OS-1
Office Service |
|
|
35 |
15 (j,k) |
10 (1) |
10 (m,n) |
|
|
B-1
Local Business |
|
|
35 |
15 (k) |
10 (1) |
10 (m,n) |
|
|
B-2
Planned Shopping Center |
|
|
35 |
75 (k,o) |
20 (o) |
30 (m,o) |
|
|
| B-3 Central Business |
|
|
(p) |
none (p) |
none |
none (m) |
|
|
B-4
General Business |
|
|
35 |
15 (k) |
(l) |
10 (m,n) |
|
|
I-1
Light Industrial |
|
|
40 |
40 (q) |
20 (r) |
(r,s) |
|
|
I-2
General Industrial |
|
|
60 |
60 (q) |
30 (r) |
(r,s) |
|
|
C-OS
Conservation Open Space |
43,560 |
66 |
35 |
50 |
50 |
(r) |
|
|
(Ordinance Code 1977, § 5.71; Ord. No. 454, § 1,
8-15-88; Ord. No.478, § 1, 11-19-90; Ord. No. 626, § 336-40 & 351,
3-17-03)

|